Scada-LTS - Privilege escalation (CVE-2022-41976)

Introduction

Description

A remote attacker, authenticated in the application as a low-privileged user, can change role (e.g., to administrator) by updating their user profile.

Disclaimer

The information contained in this disclosure is for educational and research purposes only. I am not responsible for any improper or illegal use of the details provided. It is intended to help improve the security of affected systems. System administrators and software owners are advised to take the necessary steps to mitigate the risks associated with this vulnerability. Unauthorized use of the information to exploit systems without permission is illegal and may have criminal consequences.

Exploitation

The attacker authenticated as “roommate”, it is evident that he only sees his profile data and that the menu has no administrative options.p

If we capture the request with a tool such as Burp Suite, we can see our profile data, which shows that we are not an administrator (admin=false).

But, if an attacker were to click on the “save profile data” icon, he could intercept the request and it becomes evident that the “admin”:false parameter is stored from the client side.

By modifying the parameter “admin”:false to “admin”:true, the attacker would be able to manipulate his role (possibly some more data and about other users) and assign himself other privileges.

In the following illustration, the profile with the “admin” role is shown again, evidencing the escalation of privileges and commitment of the SCADA-LTS.

If we update the application, it is now possible to see all the menu options and the rest of the users, thus contemplating the privilege escalation and the commitment of the application.

In addition, this vulnerability would allow SQL queries to be performed on the application, obtaining confidential information, creating files with malicious code for command execution or extracting encrypted user credentials for reusing passwords in other services.

Mitigation

The issue has been patched in SCADA-LTS v2.7.3, so it is recommended to upgrade as soon as possible to mitigate this deficiency.